주요 콘텐츠로 건너뛰기
도움말

현재 버전 작성자: Matt Zieminski

제목:

Everything is running but not getting cold

텍스트:

I've got a tricky fridge issue.  There are many "how too" easy fixes for the fridge/freezer and I've covered nearly all of those but still, with everything basic checked out and seemingly working, it will not get cold at the evaporators/freezer section.  Here is what I've already done/tried

* Cleaned condenser coils and fan
* Verified that both condenser fan and evaporator fan are working properly(actually replaced the evap fan- probably not needed)
* Pinned out Linear compressor with ohm meter.  No short to ground and only 1 set of pins with a readout appx 7.8  which I believe means it is ok
* Replaced compressor relay/limit switch/Thermistor assy.
* Ran the 4 stage control board "test button"  all of which passed followed by the full reset
* replaced the temp sensor in the freezer
* The compressor is definitely running/vibrating/getting warm after running for time.
* The sequencing of all the components turning on is seemingly correct.
Not sure exactly what else there is other than perhaps needing a refrigerant charge or something else I am missing.

Only notes are that

1.)I've posted in LG fridges but I really have a Kenmore. But the compressor is the LG linear type and all the PNs for replacement have been LG technically even though the match my Model (795 72043 110). I know the LG compressors have history of issues and that newer fridges generally s*ck but in theory this one should be running.

2.) Before I did the 4 stage control board test button thing it was definitely abruptly shutting itself down.

Any suggestions or help would be greatly appreciated.

기기:

-LG Refrigerator
+Kenmore Refrigerator

현황:

open

편집자: Jeff040484

제목:

Everything is running but not getting cold

텍스트:

I've got a tricky fridge issue. There are many "how too" easy fixes for the fridge/freezer and I've covered nearly all of those but still, with everything basic checked out and seemingly working, it will not get cold at the evaporators/freezer section. Here is what I've already done/tried
* Cleaned condenser coils and fan
* Verified that both condenser fan and evaporator fan are working properly(actually replaced the evap fan- probably not needed)
* Pinned out Linear compressor with ohm meter. No short to ground and only 1 set of pins with a readout appx 7.8 which I believe means it is ok
-* Replaced compressor relay/limit switch
+* Replaced compressor relay/limit switch/Thermistor assy.
* Ran the 4 stage control board "test button" all of which passed followed by the full reset
-* replaced the thermistor/sensor in the freezer
+* replaced the temp sensor in the freezer
* The compressor is definitely running/vibrating/getting warm after running for time.
* The sequencing of all the components turning on is seemingly correct.
-
Not sure exactly what else there is other than perhaps needing a refrigerant charge or something else I am missing.
Only notes are that
1.)I've posted in LG fridges but I really have a Kenmore. But the compressor is the LG linear type and all the PNs for replacement have been LG technically even though the match my Model (795 72043 110). I know the LG compressors have history of issues and that newer fridges generally s*ck but in theory this one should be running.
2.) Before I did the 4 stage control board test button thing it was definitely abruptly shutting itself down.
Any suggestions or help would be greatly appreciated.

기기:

LG Refrigerator

현황:

open

원본 게시물 작성자: Jeff040484

제목:

Everything is running but not getting cold

텍스트:

I've got a tricky fridge issue.  There are many "how too" easy fixes for the fridge/freezer and I've covered nearly all of those but still, with everything basic checked out and seemingly working, it will not get cold at the evaporators/freezer section.  Here is what I've already done/tried

* Cleaned condenser coils and fan
* Verified that both condenser fan and evaporator fan are working properly(actually replaced the evap fan- probably not needed)
* Pinned out Linear compressor with ohm meter.  No short to ground and only 1 set of pins with a readout appx 7.8  which I believe means it is ok
* Replaced compressor relay/limit switch
* Ran the 4 stage control board "test button"  all of which passed followed by the full reset
* replaced the thermistor/sensor in the freezer
* The compressor is definitely running/vibrating/getting warm after running for time.
* The sequencing of all the components turning on is seemingly correct.

Not sure exactly what else there is other than perhaps needing a refrigerant charge or something else I am missing.

Only notes are that

1.)I've posted in LG fridges but I really have a Kenmore. But the compressor is the LG linear type and all the PNs for replacement have been LG technically even though the match my Model (795 72043 110). I know the LG compressors have history of issues and that newer fridges generally s*ck but in theory this one should be running.

2.) Before I did the 4 stage control board test button thing it was definitely abruptly shutting itself down.

Any suggestions or help would be greatly appreciated.

기기:

LG Refrigerator

현황:

open