I noticed the error code on my washer as LD. So I immediately knew where to look and notice the electrical blue wire got loose and smelled burned. how do I reconnect this wire or is it unfixable.
좋은 질문 입니까?
I noticed the error code on my washer as LD. So I immediately knew where to look and notice the electrical blue wire got loose and smelled burned. how do I reconnect this wire or is it unfixable.
좋은 질문 입니까?
enzweilerswho by looking at your image it appears as if the wire came out of the connector. You could try to either replace the connector (P4 in the image) or find a way to otherwise attach the wires to the pumps. Take an image of where they plug in at the pump end, sometimes a simple spade connector can be used.
Of course, it is possible that it has failed due to the wire getting hot. Check your pump to make sure that it does not have a short and draws to many amps.
1. Unplug washer or disconnect power.
2. Disconnect the wire connector from the drain pump terminals.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to each of the drain pump terminals. The meter
should indicate between 10.5 and 14 Ω.
해당 답변은 도움이 되었습니까?
I just bought two automotive spade connectors, made pigtails of each. Then connect the spades to the terminals and connect the pigtails to the old blue wires with wire nuts or crimp connectors. Works great, and you dont have to buy a new wire harness.
해당 답변은 도움이 되었습니까?
24 시간 전: 1
7일 전: 7
30일 전: 30
전체 시간: 3,739
댓글 5개
enzweilerswho do us a favor and post a few images of this damage with your question. Use this guide 기존 질문에 이미지 추가하기 for that. This will allow us to see what you see.
oldturkey03 의
Upon inspecting the drain pumps . I noticed one of the wiring harness connectors was not making contact. I hope this helps.
enzweilerswho 의
I sent you two pics of the connector side view and front view. on top in back is where each wire is inserted. I also noticed on side is a nbr imprinted. M91886.
Thks again for your help
enzweilerswho 의
Why couldn't you reinsert the wires back into the connector? Might have to apply wire stripers to ensure electrical contact.
Thomas Collette 의
How you open de drain pump wieing cause 1 cable are its alone
Mario 의