The alarm unit is located behind the glove box. Once the glovebox is out of the way, you can remove the black plastic alarm unit, open it and change the dip switch for a less sensitive setting.

부품

지정된 부품이 없습니다.

  1. Once the glove box is out of the way, it's easy to spot the alarm unit. The green connector will be plugged into it. I had already unplugged it when I took this picture.
    • Once the glove box is out of the way, it's easy to spot the alarm unit. The green connector will be plugged into it. I had already unplugged it when I took this picture.

  2. 맥북 배터리 수리 키트

    기본 가격은 $69.99

    Buy Now

    맥북 배터리 수리 키트

    기본 가격은 $69.99

    Buy Now
  3. It may be stubborn to get out because it is stuck down with double stick foam pads.
    • It may be stubborn to get out because it is stuck down with double stick foam pads.

  4. Remove the 4 screws (may be under the foam strips). This is the bottom of the circuit board.
    • Remove the 4 screws (may be under the foam strips). This is the bottom of the circuit board.

  5. Turn the board over and locate the 2 position dip switch.
    • Turn the board over and locate the 2 position dip switch.

    • This dip switch adjusts the glass breakage microphone sensitivity

    • Sensitivity settings:

    • 1 off & 2 off = high

    • 1 on & 2 off = mid (factory setting)

    • 1 off & 2 on = low

    • 1 on & 2 on = super low

결론

To reassemble your device, follow these instructions in reverse order.