소개

The alarm unit is located behind the glove box. Once the glovebox is out of the way, you can remove the black plastic alarm unit, open it and change the dip switch for a less sensitive setting.

부품

부품은 필요하지 않습니다.

  1. 댓글 쓰기

  2. Once the glove box is out of the way, it's easy to spot the alarm unit. The green connector will be plugged into it. I had already unplugged it when I took this picture.
    • Once the glove box is out of the way, it's easy to spot the alarm unit. The green connector will be plugged into it. I had already unplugged it when I took this picture.

    댓글 쓰기

  3. Fixmas/픽스마스 분위기를 띄우세요
    FIXMAS12 코드로 $50 이상 구매시 $12 할인을 받으십시오
    Fixmas/픽스마스 분위기를 띄우세요
    FIXMAS12 코드로 $50 이상 구매시 $12 할인을 받으십시오
    • It may be stubborn to get out because it is stuck down with double stick foam pads.

    댓글 쓰기

    • Remove the 4 screws (may be under the foam strips). This is the bottom of the circuit board.

    댓글 쓰기

    • Turn the board over and locate the 2 position dip switch.

    • This dip switch adjusts the glass breakage microphone sensitivity

    • Sensitivity settings:

    • 1 off & 2 off = high

    • 1 on & 2 off = mid (factory setting)

    • 1 off & 2 on = low

    • 1 on & 2 on = super low

    댓글 쓰기

결론

To reassemble your device, follow these instructions in reverse order.