주요 콘텐츠로 건너뛰기

Alienware m15 R6 I/O board Replacement

필요한 것

  1. Alienware m15 R6 I/O board Replacement, Base Cover: 1 단계, 이미지 1/1
    • Remove the two screws (M2.5x5) that secure the base cover to the palm-rest and keyboard assembly.

    • New line. Loosen the two captive screws (M2.5x8.5+3.5) that secure the base cover to the palm-rest and keyboard assembly

    • Loosen the four captive screws (M2.5x1.7+3.3) that secure the base cover to the palm-rest and keyboard assembly.

  2. Alienware m15 R6 I/O board Replacement: 2 단계, 이미지 1/1
    • Using your fingertips, pry open the base cover from the middle of the front edge of base cover, and then pry the left and right sides of the base cover.

    • Lift the base cover off the palm-rest and keyboard assembly.

  3. Alienware m15 R6 I/O board Replacement: 3 단계, 이미지 1/1
    • Disconnect the battery cable from the system board.

    • Turn your computer over and press the power button for 20 seconds to drain the flea power

  4. Alienware m15 R6 I/O board Replacement, I/O board: 4 단계, 이미지 1/1
    • Lift the system board Mylar and open the latch to disconnect the I/O-board cable from the system board.

    • Open the latch to disconnect the I/O-board cable from the I/O board.

    • Remove the screw (M2x4) that secures the I/O board to the palm-rest and keyboard assembly.

    • Loosen the captive screw (M2x2) that secures the I/O board to the palm-rest and keyboard assembly. (skip for NVIDIA GeForce RTX 3050 Ti discrete GPU controller)

    • Lift the I/O board off the palm-rest and keyboard assembly.

결론

To reassemble your device, follow these instructions in reverse order.