Follow this guide to remove the access door of an India Mark II for repair or replacement.

  1. Before performing any repairs, perform a water test on the pump by raising and lowering the handle a full 40 strokes. A properly performing pump will yield greater than 10 liters. Remove the hex head bolt from the top of the access door on the pump head.
    • Before performing any repairs, perform a water test on the pump by raising and lowering the handle a full 40 strokes. A properly performing pump will yield greater than 10 liters.

    • Remove the hex head bolt from the top of the access door on the pump head.

    • On reassembly, this bolt should be hand-tight.

  2. 맥북 배터리 수리 키트

    기본 가격은 $69.99

    Buy Now

    맥북 배터리 수리 키트

    기본 가격은 $69.99

    Buy Now
  3. Pull the access door straight up off the pump head. Store the access door in a sanitary place to prevent contamination. Store the access door in a sanitary place to prevent contamination.
    • Pull the access door straight up off the pump head.

    • Store the access door in a sanitary place to prevent contamination.

  4. The access door has a tongue that fits into the base of the pump head. The access door makes a convenient tray to hold nuts and bolts during the disassembly.
    • The access door has a tongue that fits into the base of the pump head.

    • The access door makes a convenient tray to hold nuts and bolts during the disassembly.

결론

To reassemble your device, follow these instructions in reverse order.