주요 콘텐츠로 건너뛰기

소개

The oscillation gear swivels the head of the fan back and forth by translating power from the motor into the oscillation arm.

도구

부품

지정된 부품이 없습니다.

  1. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement, Front Cage: 1 단계, 이미지 1/2 Insignia NS-F12R6-SS Upper Oscillation Gear Replacement, Front Cage: 1 단계, 이미지 2/2
    • Unplug your fan.

    • Remove the 20 mm bolt that fastens the fan ring located at the bottom of the fan cage with a Phillips #3 screwdriver.

  2. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 2 단계, 이미지 1/1
    • Remove the ring that runs around the edge of the fan cage.

  3. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 3 단계, 이미지 1/1
    • Remove the front of the fan cage.

  4. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement, Fan Blade: 4 단계, 이미지 1/1
    • Remove the 8 mm bolt fastening the fan blades to the rotor with a Phillip #3 screwdriver.

  5. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 5 단계, 이미지 1/1
    • Take caution when removing the fan blades. They can be sharp!

    • Slide the fan blade off the end of the rotor.

  6. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement, Back Cage: 6 단계, 이미지 1/1
    • Unscrew the four 8 mm bolts that fasten the back of the fan cage back to the motor housing with a Phillips #3 screwdriver.

  7. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 7 단계, 이미지 1/1
    • Pull the back cage off.

  8. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement, Oscillation Button: 8 단계, 이미지 1/2 Insignia NS-F12R6-SS Upper Oscillation Gear Replacement, Oscillation Button: 8 단계, 이미지 2/2
    • Unscrew the 10 mm screw in the center hole of the oscillation knob with a Phillips #3 screwdriver.

  9. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 9 단계, 이미지 1/1
    • Remove the oscillation knob.

  10. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement, Motor Housing: 10 단계, 이미지 1/1
    • Use your fingers to gently pull the power knob directly away from the motor housing.

  11. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 11 단계, 이미지 1/1
    • Unscrew the flat 17 mm nut fastened at the bottom of the power knob with a small crescent wrench.

  12. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 12 단계, 이미지 1/2 Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 12 단계, 이미지 2/2
    • Remove the four 6 mm bolts and small washers that secure the front face of the motor housing with a Phillips #3 screwdriver and remove the washers.

  13. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 13 단계, 이미지 1/1
    • Pull the front face of the motor housing off toward the front of the rotor.

  14. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 14 단계, 이미지 1/2 Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 14 단계, 이미지 2/2
    • Remove the 10 mm triangular-headed bolt with a Phillips #3 screwdriver.

  15. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 15 단계, 이미지 1/1
    • Slide the back end of the motor housing away from the front of the rotor.

  16. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 16 단계, 이미지 1/1
    • Remove the small piece of paper hanging on the power button.

  17. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement, Upper Oscillation Gear: 17 단계, 이미지 1/3 Insignia NS-F12R6-SS Upper Oscillation Gear Replacement, Upper Oscillation Gear: 17 단계, 이미지 2/3 Insignia NS-F12R6-SS Upper Oscillation Gear Replacement, Upper Oscillation Gear: 17 단계, 이미지 3/3
    • Using a Phillips #3 screwdriver, unscrew and remove the 7 mm long bolt and small washer fastening the yellow and green wire to the motor housing support.

  18. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 18 단계, 이미지 1/2 Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 18 단계, 이미지 2/2
    • Using a Phillips #3 screwdriver unscrew the 13 mm long screw fastening the motor housing support to the oscillation gear box.

  19. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 19 단계, 이미지 1/3 Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 19 단계, 이미지 2/3 Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 19 단계, 이미지 3/3
    • Using a Phillips #3 screwdriver, unscrew the three 13 mm long screws fastening the grey plate to the top of the oscillation gear box.

    • Remove the grey cap covering the oscillation gear box.

  20. Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 20 단계, 이미지 1/2 Insignia NS-F12R6-SS Upper Oscillation Gear Replacement: 20 단계, 이미지 2/2
    • Remove the upper oscillation gear.

결론

To reassemble your device, follow these instructions in reverse order.