This guide will demonstrate the proper procedure to remove the back panel without damaging the internals of the camera so that you can access a variety of the components hidden behind it.

부품

지정된 부품이 없습니다.

  1. Remove the two visible 6.0 mm Philips #0 screws on the left and right sides of the viewfinder. These screws are highlighted in red.
    • Remove the two visible 6.0 mm Philips #0 screws on the left and right sides of the viewfinder. These screws are highlighted in red.

  2. Remove the four 6.0 mm Philips #0 screws on the left and right sides of the camera. Remove the four 6.0 mm Philips #0 screws on the left and right sides of the camera.
    • Remove the four 6.0 mm Philips #0 screws on the left and right sides of the camera.

  3. Remove the four highlighted 3.0 mm Philips #0 screws on the bottom of the camera.
    • Remove the four highlighted 3.0 mm Philips #0 screws on the bottom of the camera.

  4. While pulling the bottom down, remove the back of the camera.
    • While pulling the bottom down, remove the back of the camera.

    • Be careful not to pull too hard on the back as it is connected via a ribbon cable. Be sure to disconnect this cable on the main board.

    • To disconnect the ribbon cable pull the small black tab upward and pull gently on the cable.

결론

To reassemble your device, follow these instructions in reverse order.