  1. Oral-B Vitality Power Button Replacement, Power Button: 1 단계, 이미지 1/3 Oral-B Vitality Power Button Replacement, Power Button: 1 단계, 이미지 2/3 Oral-B Vitality Power Button Replacement, Power Button: 1 단계, 이미지 3/3
    • Using the pliers, rotate the head base 90 degrees counterclockwise and remove core from the handle.

  2. Oral-B Vitality Power Button Replacement: 2 단계, 이미지 1/1
    • Locate the 4 terminals connecting the power button to the circuit board.

  3. Oral-B Vitality Power Button Replacement: 3 단계, 이미지 1/3 Oral-B Vitality Power Button Replacement: 3 단계, 이미지 2/3 Oral-B Vitality Power Button Replacement: 3 단계, 이미지 3/3
    • Desolder the 4 terminals and remove the old button.

    • Remove as much of the old solder as possible.

  4. Oral-B Vitality Power Button Replacement: 4 단계, 이미지 1/1
    • Attach the new button by soldering the 4 terminals with new solder.

결론

To reassemble your device, follow these instructions in reverse order.

다른 8명이 해당 안내서를 완성하였습니다.

Grady Bennett

회원 가입일: 11/07/17

500 평판

안내서 2개 작성하였습니다

IUPUI, Team S2-G1, Harley Fall 2017 IUPUI, Team S2-G1, Harley Fall 2017 회원

IUPUI-HARLEY-F17S2G1

3 회원들

안내서 8개 작성하였습니다

댓글 4개

In my case no need to change the button, just redo the solder and this is it.

the vibration has damaged the solder.

Al kri - 답글

If you try to unsolder the battery it has some protection and it won't work anymore

Gigi Kent - 답글

Before unsoldering the button, you can understand if it is good or not just bypassing it with a wire: with a copper wire you can touch two pins of the button (one on the right side, on on the left side); if the toothbrush starts and stop on each touch of the wire, the problem is the button. I recognize the problem in this way.

Manolo Cerello - 답글

True except if the switch is permanently “on”. I think that was my case. Replacing the switch fixed the issue.

Mumble Tim -