Skip to main content

Repair and disassembly guides for the Apple AirPort Extreme Model A1143.

10 질문 전체 보기

Not working i.e. no power, no light on

we have a airport extreme 5th gen. unit has quit working i.e. like no power, light is not on. Power supply checks good. does this unit have a fuse or ? or is it just dead now ?

답변되었습니다! View the answer 저도 같은 문제를 겪고 있습니다

좋은 질문 입니까?

점수 3
의견 추가하세요

아이폰 배터리 수리 키트

Only $29.99

Buy Now

아이폰 배터리 수리 키트

Only $29.99

Buy Now

2개의 답변

선택된 해법

Hard to tell here if you can fix it without opening it up and testing a few points for voltage.

Are you able to solder SMT devices? Do you have a DVM? Do you have the skills to diagnose electrical circuits?

해당 답변은 도움이 되었습니까?

점수 1

댓글:

Where can I learn this ??

My AirPort Extreme has the same problem and I'd love to crack it open and start troubleshooting. I just wouldn't know where to start.

의 답변

Where do you live and what schooling have you had?

Did you review the IFIXIT guides? Apple AirPort Extreme Model A1143 Repair While these explain the action of replacing parts it doesn't get into the brass tacks of understanding microelectronics.

의 답변

Exactly! I'm looking to understand the brass tacks.

I have a software background. I took a course or two on digital circuits but I have no practical experience.

의 답변

Where do you live?

의 답변

Canada (Toronto area)

의 답변

의견 추가하세요
가장 유용한 답변

Listen to the power supply (right next to your ear!). Can you hear a screech each time the green LEDs on the ethernet ports blink on and off? I tested mine with a multimeter and while it delivers 12V, it is not supplying the necessary power for the AEBS. You can buy replacement power supplies on Amazon or eBay for very little dough. Cheaper than buying a new WiFi router anyway.

해당 답변은 도움이 되었습니까?

점수 4

댓글:

I plugged in the power supply and instantly heard the screeching sound. Plugged into Airport and it became intermittent but no light turned on the Airport extreme. So I am going with replacing the power supply. It quit after a power outage.

의 답변

Dead power supplies still show 12VDC when a meter is applied. They just don't supply the power necessary to allow the AEBS to function. Replacement power supples are available <https://www.ebay.com/bhp/airport-extreme...>

의 답변

의견 추가하세요

귀하의 답변을 추가하십시오

Geo 가/이 대단히 고마워 할 것입니다.
조회 통계:

지난 24시간: 5

지난 7일: 35

지난 30일: 137

전체 시간: 3,730