What is wrong with my 42″ Wind Curve® Platinum with Remote Control?

I took it apart to clean it i've done it before but this time i after i put it back together about a minute after i turned it on it turned off. It only turns on when speed is on 3,when you turn it down to 2 from 3 it feels like speed 1.If you turn it from 3 to 1 the fan blade stops. If you turn it from 3 to 1 or 2 to 1 the fan blade stops spinning, but if the blade does not fully stop yet and u turn it from 1 to 3 or 1 to 2 it keeps spinning. everything seems to be fine with it accept the fan blade spinning when or how fast its supposed to. What the heck is wrong with it?

이 질문에 답하기 저도 같은 문제를 겪고 있습니다

좋은 질문 입니까?

점수 0
댓글 달기

답변 1개

The Switch might be going bad. Unfortunately, unless you have solder experience, replacing the switch would be difficult. Only other thing I could think of is dust/gunk build up around the motor, does the motor feel hot when the device is on setting 1?

If YES: then the fan is still on and again best thing I can say it to try and clean around the motor and put some wd-40 around the gears (make sure its unplugged when you do this) and try not to get any of the wd-40 on any of the electrical components.

If NO: then the switch is faulty and is turning the fan off when on the 1 setting. it will need to be replaced.