주요 콘텐츠로 건너뛰기

This receiver is Bluetooth Ready, has 110 Watts x 5 Direct Energy Amplification and is iPad / iPhone Certified with supplied cable

26 질문 전체 보기

The device switches off after the second relais click

Hi,

I have a VSX-922 but I assume this doesn't make a big difference.

The received worked fine for years but recently just shut off during normal use. If I now try to turn it on, the device powers up, the display shows "STEREO", and I can hear the first relais click. But immediately after the second relais click the device shuts off and the iPod LED starts blinking.

Any ideas what might be wrong with it?

이 질문에 답하기 저도 같은 문제를 겪고 있습니다

좋은 질문 입니까?

점수 0
댓글 달기

답변 1개

According to the service manual, this is an indication of either "AMP overload" or "abnormal DC voltage in the power supply". I would expect that the problem is in the AMP section as this is the most common failure. Since this unit uses discrete transistors as outputs, I expect to find at least one that is shorted which would cause the symptom you describe. If you are comfortable working on these, finding and changing the outputs should be relatively easy. Always change them in pairs. This is because when one fails it places extreme stress on the other one in the pair.

Hope this helps,

Dan

해당 답변은 도움이 되었습니까?

점수 0
댓글 달기

귀하의 답변을 추가하세요

Roger Rabbit 님은 대단히 고마워 할 것입니다.
조회 통계:

24 시간 전: 0

7일 전: 1

30일 전: 5

전체 시간: 2,211