Dear,

Circuit priming message loops at beginning, then straigth away E05 error and asking to restart the machine, I did few times without sucess.

I opened the machine, and I can`t see any leak.

Any recommendation please?

My  coffee machine is Royal gran crema

답변되었습니다! 답변 보기 저도 같은 문제를 겪고 있습니다

좋은 질문 입니까?

점수 0
댓글 1개

Hi . The problem with E05 is generated of many SAECO coffee machine , I had this problem and I fixed it . See the video below and I am sure it will helps you .

https://youtu.be/0YR-xtacx1U

댓글 달기

답변 1개

선택된 답변

Error code 05 means that the flow meter does not give a signal. Now you have to search: is the flowmeter blocked or broken? Or the water cannot pass through, e.g. because the heater or the pump is calcified. In Saeco Royal Pumpe austauschen the flowmeter can be seen in step 6, picture 2. Open the flowmeter and clean it, it's easy.

해당 답변은 도움이 되었습니까?