주요 콘텐츠로 건너뛰기

This is an older equipment line from Saeco. All are labeled Sup 018. (Badge on the bottom). They were later sold under the name Spidem Trevi

13 질문 전체 보기

Saeco Vienna grinds beans but doesn't stop grinding or proceed to brew

First my Saeco is NOT a Sup 018, just a Vienna probably because it is 20+ yrs old. I have determined the grounds are not being dumped from the collector into the brew group because the solenoid is not being activated. However I do not know whether the solenoid is bad or whatever determines there are enough grounds has failed.

What triggers the 'dump-the-shot' action?? is my basic question.

이 질문에 답하기 저도 같은 문제를 겪고 있습니다

좋은 질문 입니까?

점수 0
댓글 달기

답변 2개

There is a microswitch that sends a signal to the circuit board which starts the doser solenoid and the brewing cycle. Could just require dismantling and cleaning or new switch. Worst case new circuit board. Unlikely it is the solenoid Most likely needs cleaning.

해당 답변은 도움이 되었습니까?

점수 0
댓글 달기

Google for "Saeco Vienna Testmode". This will help determining the issue, e.g. this video. I see two possibilities: the microswitch of the grind chamber, as mentioned above, hopefully a cleaning ist sufficient, maybe a replacement of the switch. You will find the chamber following the outlet of the ginder.

Or worse: a faulty PCB, in this case a replacement is an option. Much cheaper is the replacement of some parts on the PCB, there are repairkits. Good luck!

해당 답변은 도움이 되었습니까?

점수 0
댓글 달기

귀하의 답변을 추가하세요

Ken Sharples 님은 대단히 고마워 할 것입니다.
조회 통계:

24 시간 전: 0

7일 전: 1

30일 전: 5

전체 시간: 74