주요 콘텐츠로 건너뛰기

Guides and repair information for dryers produced by Bosch, a German engineering and technology company.

5 질문 전체 보기

What sensor can cause F09 fault? Machine stops, clothes are still wet.

During the cycle my machine stops running displaying F09 fault. The cloths in the machine are still wet. I can restart the dryers, but sometimes it stops again, sometimes it keeps running till the end. When the machine complete the full cycle, sometime cloths are still not dry however the sensor should measure this. How can I find if the humidity sensor is failing or the over temp sensor is failing or......

이 질문에 답하기 저도 같은 문제를 겪고 있습니다

좋은 질문 입니까?

점수 0
댓글 달기

답변 1개

가장 유용한 답변

Doing a search indicates that your dryer temperature sensor has failed. "NTC" broke. Ntc is a thermistor. You should be able to replace it.

Block Image

해당 답변은 도움이 되었습니까?

점수 1

댓글 1개:

Hey thanks,

I will find how to replace the the NTC, This will be probably the root cause.

I will leave a message when it is replaced.

댓글 달기

귀하의 답변을 추가하세요

Hans dusar 님은 대단히 고마워 할 것입니다.