주요 콘텐츠로 건너뛰기

Uninterruptible power supply, uninterruptible power source, UPS 또는 battery/flywheel backup은 (일반적으로 주전원) 입력 전원이 고장났을때 비상 전원을 공급하는 전기 장치입니다.

42 질문 전체 보기

it won't charge the battery...

My CyberPower CP1500PFCLCD didn't know how old the battery was. I input the age and now it won't charge the battery...

이 질문에 답하기 저도 같은 문제를 겪고 있습니다

좋은 질문 입니까?

점수 0
댓글 달기

답변 1개

@razvanburghiu sounds like the UPS software has turned the charging off because off the age off the battery. How old is the battery and where and how did you enter the age? Did it charge that battery before you did that? I would suggest that you actually check the battery under a load and make sure it is still chargeable. If not then you most likely need to go ahead and replace it.

해당 답변은 도움이 되었습니까?

점수 0

댓글 2개:

Just added it in the PowerPanel Business interface.

It was not having issues before.

It's working now, it just spontaneously started charging again, so, freaking random. I have another model that is doing the same thing, but that one is a simulated sine wave model, and while the battery works, it's doing the same thing, not charging even after power is back.

@razvanburghiu I wonder if this is a software issue (dodgy software) or a manufacturer's intent to ensure that you have a good battery. I wonder if they "force" you to use batteries that are of certain age.

댓글 달기

귀하의 답변을 추가하세요

Razvan Burghiu 님은 대단히 고마워 할 것입니다.
조회 통계:

24 시간 전: 0

7일 전: 0

30일 전: 4

전체 시간: 25