주요 콘텐츠로 건너뛰기

Eureka EasyClean 71C Motor Replacement

필요한 것

  1. Eureka EasyClean 71C Motor Replacement, Bottom Cover: 1 단계, 이미지 1/1
    • Unscrew the two 18.1 mm PH2 Phillips head screws on the bottom of the vacuum.

  2. Eureka EasyClean 71C Motor Replacement: 2 단계, 이미지 1/1
    • Pry off the Riser Visor using the plastic opening tool.

  3. Eureka EasyClean 71C Motor Replacement: 3 단계, 이미지 1/1
    • Remove the screw cap using the metal spudger.

    • First-time removal of the screw cap can be difficult. The screw cap isn’t vital, so don’t worry about damaging the screw cap and just keep trying until it comes out.

  4. Eureka EasyClean 71C Motor Replacement: 4 단계, 이미지 1/2 Eureka EasyClean 71C Motor Replacement: 4 단계, 이미지 2/2
    • Unscrew the 14mm PH2 Phillips head screw.

    • Pull the bottom cover off of the rest of the casing.

  5. Eureka EasyClean 71C Motor Replacement, Casing: 5 단계, 이미지 1/1
    • Pull the power switch all the way up and remove the dust cup.

  6. Eureka EasyClean 71C Motor Replacement: 6 단계, 이미지 1/2 Eureka EasyClean 71C Motor Replacement: 6 단계, 이미지 2/2
    • Unscrew the six 18.1mm PH2 Phillips head screws on the side of the vacuum.

    • Pull the casing apart.

  7. Eureka EasyClean 71C Motor Replacement, Motor: 7 단계, 이미지 1/1
    • Pull out the switch board.

    • Ensure the vacuum is turned off and unplugged before handling any of the electronics.

  8. Eureka EasyClean 71C Motor Replacement: 8 단계, 이미지 1/2 Eureka EasyClean 71C Motor Replacement: 8 단계, 이미지 2/2
    • Desolder the pictured red and black wires.

    • For instructions on how to solder and desolder wires, visit this guide.

결론

To reassemble your device, follow these instructions in reverse order.