AV-S Ventilator

174 페이지 · 9.70 MB · PDF

AV-S Ventilator

Introduction

Partnership for Life

AV-S Ventilator

Product Overview

Introduction

Characteristics

Configuration

Sub-assemblies

AV-S Ventilator

Operation

Ventilator control settings

Operation workshop

Pre-operative checkout procedure

AV-S Ventilator

TECHNICAL DESCRIPTION

AV-S Pneumatic description.

AV-S Electrical description.

AV-S Ventilator

Practical:

Disassembly.

Planned maintenance.

Test and calibration procedures.

Fault finding.

AV S ventilator

Product Overview

Partnership for Life

Aims and Objectives

Aim:

The aim of this module is to give the student a full understanding of the features and characteristics of the AV-S ventilator.

Objective:

♦ By the end of this module the student will be able to:

Describe the features of the AV-S.

Recognise user controls.

Recognise AV-S configuration.

AV-S Ventilator

Pneumatically driven.

Software controlled.

Multi-mode ventilator.

Time-cycled, volume/pressure controlled and pressure limited.

Compliance & fresh gas compensated.

User adjustable sigh & inspiratory pause.

AV-S monitoring

Integrated monitoring:

Inspired oxygen measurement.

Measured from inspiratory limb.

Airway pressure measurement.

Measured in the expiratory limb.

Tidal/Minute volume measurement.

Dual spirometry system.

AV-S features

Large 8.4" high definition colour screen.

Touch screen.

Rotary control dial.

Single/ Dual waveform display.

Designed to integrate with:

PrimaSP; SP2 and SP3.

A100SP; A200SP.

AV-S features

Print outs & interfacing:

USB, Serial Port, Analogue outputs, HPPCL4 printer output.

30 minutes battery back up as standard:

Optional 60 minute battery available.

AV-S features

Membrane keys

LED power indicators:

Yellow when connected / battery

charging

LED on/off indicator.

Green when switched on

Menu selection key

Image

AV-S

AV-S

On/Off Switch

Alarm silence/mute key.

Rotary control dial.

Partnership for Life

Modes of ventilation

Mandatory modes:

Volume Mode.

Pressure Mode.

Spontaneous breathing support modes:

SIMV.

SMMV.

Pressure Support.

Partnership for Life

Modes of ventilation

Volume Controlled Ventilation

◆ AV-S delivers a mandatory set volume of gas at fixed breath intervals.

The Patient is making no respiratory effort.

♦ AV-S is volume limited and time cycled.

♦ Tidal volume setting range, 20 to 1600ml.

Inspiration terminated after a preset time.

Modes of ventilation

Airway Flow and Pressure Patterns

Image

Modes of ventilation

Volume ventilation parameter limits:

Tidal volume adjustable from 20 – 1600 mL

Rate adjustable from 4 – 100 bpm

I:E ratio adjustable from 1:0.3 – 1:8

♦ Peep 'Off or adjustable from 4 – 20 cmH $ _{2} $O

Inspiratory pressure limit from 10 to 80 cmH $ _{2} $O

Inspiratory pause 0-60%

Does not affect I:E ratio

Sigh 1.5 x Set Vt

Adjustable 1:10 to 1:100 breaths

Partnership for Life

1.87.xx display

Image

Litres 10 0.8 0.6 0.4 0.2 0.0 -10 cmH₂O 60 50 40 30 20 10 0 0 0 0 0 0 0 0 0 0 V_T SET mL 600 mL SET bpm 10 SET: E