주요 콘텐츠로 건너뛰기
도움말

현재 버전 작성자: oldturkey03

텍스트:

@ddugan the 4 times blink error is usually a Temp or a Fan error. For probable causes you need to check
- Fan1-4 Power is not supplied. (GI board)
- Fan connector is not seated securely.
- Fan caught wires or harnesses.
- Internal temperature is too high.
-- IIC-E line connector(H4 board) is not seated properly.
+- IIC-E line connector(H4 board) is not seated properly.
+
+Try to see if you can get into the Self Diagnosis Screen. Unplug your set for a few minutes. Plug it back in. In standby mode, press the buttons on the Remote Commander sequentially, '''in rapid succession''' as shown below:
+Display==> Channel 5==>Sound Volume (-)==>Power
+Let us know what your diagnostic screen displays.

현황:

open

편집자: oldturkey03

텍스트:

@ddugan the 4 times blink error is usually a Temp or a Fan error. For probable causes you need to check
- Fan1-4 Power is not supplied. (GI board)
- Fan connector is not seated securely.
- Fan caught wires or harnesses.
-- No picture/No sound
-
- Internal temperature is too high.
- IIC-E line connector(H4 board) is not seated properly.

현황:

open

원본 게시물 작성자: oldturkey03

텍스트:

@ddugan  the 4 times blink error is usually a Temp or a Fan error. For probable causes you need to check

- Fan1-4 Power is not supplied. (GI board)

- Fan connector is not seated securely.

- Fan caught wires or harnesses.

- No picture/No sound

- Internal temperature is too high.

- IIC-E line connector(H4 board) is not seated properly.

현황:

open