주요 콘텐츠로 건너뛰기

Decorational lighting used around the holidays.

26 질문 전체 보기

Faulty section in LED icicle light string.

We have a 960 LED icicle light string, one section does not light up. I have tested the light string with a no contact voltage detector, all of the wires and bulbs in the section that doesn’t light up show live voltage. The section goes from 2 wires to 3 wires and then back to 2 wires. All the 3 wires in the faulty section show live voltage, as do all the bulbs. How can I fix this?

이 질문에 답하기 저도 같은 문제를 겪고 있습니다

좋은 질문 입니까?

점수 0
댓글 달기

답변 1개

when testing with an NCV, one side of the line will show nothing, the other will show voltage. Your tests would indicate there is an open return. IE, the neutral is not connected in that string. A connected string will show varying levels of voltage as you approach the neutral side.

해당 답변은 도움이 되었습니까?

점수 0
댓글 달기

귀하의 답변을 추가하세요

stevebrearey 님은 대단히 고마워 할 것입니다.