Is there a reset switch?
there is power to the lights control board wont light up and compressor not coming on
좋은 질문 입니까?
there is power to the lights control board wont light up and compressor not coming on
좋은 질문 입니까?
Theory wise, the control board requires a signal from the freezer temp sensor to run the compressor.
Then the control board supplies power to the compressor.
So, if there is obvious signs of power (lights), then either the control board is not getting a signal to start the compressor, (wiring or thermistor problem), the control board is defective, or the compressor or maybe a start capacitor on the compressor is bad.
I have found a number of control boards with bad capacitors.
해당 답변은 도움이 되었습니까?
24 시간 전: 1
7일 전: 3
30일 전: 20
전체 시간: 20
Can you verify your exact model number?
Matt Zieminski 의