Older model Mr. Heater, MH50K, replaced dry rotted hoses and had to play with adjustment to get to burn but it runs for 30 seconds and then stops. All I have to do is power off and back on and it will run another 30 seconds. Doesn't seem to be the limit switch because I can unplug it and it will still run the 30 seconds. I don't see any other safeties for this. Any ideas?

이 질문에 답하기 저도 같은 문제가 있습니다

좋은 질문입니까?

점수 0
댓글 달기

답변 1개

가장 유용한 답변

Hi @tatertater80500

Wonder if it's a problem with the flame sensor (part ID #31 in the parts list linked below)

Here's the parts list and wiring diagram that may help, so that you can check it out.

이 답변이 도움이 되었나요?

점수 2

댓글 1개:

Thank you. You are right the flame sensor had failed. I just didn't have one to try when I was troubleshooting it and didn't want to jump it. I used my multimeter and sure enough no continuity, but I wasn't sure. Visited local HVAC store and bought one for a home furnace which I had to do a little MacGyver on to plug in and mount, but it works! Thank you for your idea and schematic. That's always a big help.

댓글 달기

답변을 추가하세요

Tater Tater 영원히 감사할 것입니다.